3–7Operation
3.3.5 RF power reading and selector switch
The Transmitter Controller has a digital panel meter which displays Forward RF 
Power and Reverse RF Power as detected by the RF power sampler attached to the 
end of the combiner. The reading on the display is determined by the setting of the 
selector switch and accompaning green LED indicator. The readings are in 
KiloWatts and have an accuracy of better that 2%. However, it is recommended that 
an external watt meter be used for a more accurate reading. See illustration 3-7 for 
the location of the panel meter and selector switch with accompaning green LED 
indicators.
Illustration 3-7 RF Power Reading and Selector Switch