Crown FMX250 Manual do Utilizador Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 24
3–6
FM4000 Users Manual
The Transmitter Controller has the ability to internally set the maximum RF output 
power for the 4000 watt system using the power control setting for each PA. These 
controls are located behind the front panel and have an access hole in front of each 
control. A small flat blade screwdriver is needed to adjust each control. For 
maximum output level, these controls need to be set fully Clock-wise. Adjust the 
controls for each PA seperately (PA1 and PA2) in small steps (less than 100 watts 
difference) to prevent any unnecessary VSWR problems to the other amplifier (the 
one not being adjusted). These controls will effect the final RF output power that the 
remote control can adjust to. Whatever these are set for as a maximum level, that 
level is all the higher the remote control will be able to set the power to. See 
illustration 3-6 for location of these controls.
Illustration 3–6 Power Control Adjustment location
3.3.4 Raise/Lower RF Power Control
3.3.3 Transmitter RF Power Control
The Transmitter Controller has the ability to Raise or Lower the RF Power in 
small increments using the control switches on the front panel. Refer to 
illustration 3-6 for the location of these controls. To raise the power, depress 
the switch under the "Raise" lable. Press and hold this switch to change the 
power in 40 watts/second increments. Pressing once should only change the 
power 20 watts. To lower the power, depress the switch under the "Lower" 
lable. Press and hold this switch to change the power in 40 watts/second 
incriments. Pressing this switch once will change the power 20 watts. Both 
switches are momentary contact type switches and parallel the remote control 
for Raising and Lowering power via Port A on the back of the unit. A remote 
control unit is not required for this operation. These controls will change the 
RF output power on both PA's simultaneously, reducing the need for seperate 
controls for each PA.
Vista de página 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 43 44

Comentários a estes Manuais

Sem comentários