2–
10
2.6Remote I/O Connection
Port A
Pin Description
1 N/C
2 N/C
3 Ground
4 Remote RF Power RAISE - Momentary to Gnd to raise power 20 watts/second
5 Cabinet Temperature - 0.01 Volts/degrees Celsius reading of internal cabinet temp.
6 Ground
7 Remote High Voltage ON/OFF - Hold to ground to turn ON High Voltage
8 Fault Summary - TTL Logic HIGH (+5 VDC) when any fault light is ON
9 Ground
10 N/C
11 N/C
12 N/C
13 N/C
14 N/C
15 Remote RF Power LOWER - Momentary to Gnd to lower power 20 watts/second
16 N/C
17 N/C
18 Remote RF Power, Forward - 1 VDC = 1000 Watts of Forward power
19 N/C
20 N/C
21 Remote RF Power, Reverse - 1 VDC = 1000 Watts of Reverse power
22 N/C
23 N/C
24 N/C
25 N/C
1
25
13
14
The DB-25 pin connections PA1-PA5 (on the back of the controller) are where the
DB-25 Male-to-Male cables are attached from the individual PA2000's. Use PA1 for
the top amplifier and PA2 for the bottom amplifier.
The additional I/O connections on the back of the controller consist of 2 main ports;
Port A (DB-25 Female) and Port C (DB-37 Female) . Port B (DB-37) is not used in
the FM4000.
Port A has the metering and control of the System and Port C has the individual
amplifier metering channels available from each of the PA2000's.
Other I/O ports are for the reflectometer (DB-9 Female) and an unused power control
port (DB-9 Male). I/O port A is described in illustration 2-15 and I/O port B is
described in illustration 2-16.
Illustration 2-15 Remote I/O Port A Female DB-25