INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER
EXPOSED CLOSET AND URINAL INSTALLATIONS
LIMITED WARRANTY
Sloan Valve Company warrants its Crown II
®
and Crown
®
Flushometers to be made of first class materials, free from defects of material or
workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when
properly installed and serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, Sloan Valve
Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at
customer's cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other
incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company's products directly from Sloan
Valve Company for purpose of resale.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
PRIOR TO INSTALLATION
Before you install the Sloan Crown II and Crown
Flushometer, be sure the items listed below are
installed. Also, refer to the rough-in diagrams
below.
• Closet/urinal fixture
• Drain line
• Water supply line
Important:
• ALL PLUMBING SHOULD BE INSTALLED IN
ACCORDANCE WITH APPLICABLE CODES
AND REGULATIONS.
• WATER SUPPLY LINES MUST BE SIZED TO
PROVIDE AN ADEQUATE VOLUME OF WATER
FOR EACH FIXTURE.
• FLUSH ALL WATER LINES PRIOR TO MAKING
CONNECTIONS.
The Sloan Crown II and Crown Flushometer is
designed to operate with 10 to 100 psi (69 to
689 kPa) of water pressure. THE MINIMUM
PRESSURE REQUIRED TO THE VALVE IS
DETERMINED BY THE TYPE OF FIXTURE
SELECTED. Consult fixture manufacturer for
minimum pressure requirements. Most Low
Consumption water closets (1.6 gpf/6.0 Lpf)
require a minimum flowing pressure of 25 psi
(172 kPa).
TOOLS REQUIRED FOR
INSTALLATION
• Straight blade screwdriver
• Sloan A-50 Super-Wrench™, Sloan A-109
Plier Wrench or smooth jawed spud wrench
Closet Flushometer
for 1½” Back Spud
Crown II & Crown 120
VALVE ROUGH-IN
Urinal Flushometer
for 1¼” Top Spud
Crown II & Crown 180
Urinal Flushometer
for ¾” Top Spud